Specifications
|
Insertion type
|
In-line type
|
Media Compatibility
|
Air, Nitrogen
|
Pipe diameter
|
DN25~900mm
|
DN15~300mm
|
Flow velocity range
|
0.6~60Nm/s or 0.9~90Nm/s or 1.2~120Nm/s
|
Accuracy
|
0.5% RD+ ±1.5% FS
|
Temperature of medium
|
-40~+150°c
|
Pressure of medium
|
1.6MPa
|
4.0Mpa
|
Power supply
|
DC13.5~42V
|
Response time
|
1 second
|
Output
|
Frequency as standard, pulse and RS485 as optional
|
Communication
|
RS~485 as standard , 4~20mA@HART as optional
|
Date displayed
|
Mass flow, Volume flow in normal condition
Total flow , Temperature of medium. Velocity
|
Ingress protection grade
|
IP65 (GB China)
|
Measurement range
Pipe size (mm)
|
Pipe size
(inch)
|
Option 1
(0.3~30 Nm/s)
|
Standard
(0.6~60 Nm/s)
|
Option 2
(0.9~90 Nm/s)
|
Option 3
(1.2~120 Nm/s)
|
Min
(Nm3
/hr)
|
Max
(Nm3
/hr)
|
Min
(Nm3
/hr)
|
Max
(Nm3
/hr)
|
Min
(Nm3
/hr)
|
Max
(Nm3
/hr)
|
Min
(Nm3
/hr)
|
Max
(Nm3
/hr)
|
25 mm
|
1“
|
0.53
|
53
|
1.05
|
105.9
|
1.58
|
158.8
|
2.11
|
211.8
|
32 mm
|
1 1/4"
|
0.87
|
86.7
|
1.73
|
173.5
|
2.6
|
260.3
|
3.47
|
347.1
|
40 mm
|
1 1/2"
|
1.36
|
135.6
|
2.71
|
271.1
|
4.06
|
406.7
|
5.42
|
542.3
|
50 mm
|
2"
|
2.12
|
211.9
|
4.23
|
423.7
|
6.35
|
635.5
|
8.47
|
847.4
|
65 mm
|
2 1/2"
|
3.58
|
358.1
|
7.1
|
716.1
|
10.7
|
1074.1
|
14.3
|
1432.2
|
80 mm
|
3"
|
5.42
|
542.3
|
10.8
|
1084.7
|
16.2
|
1627.1
|
21.6
|
2169.4
|
100 mm
|
4"
|
8.47
|
847.5
|
16.9
|
1694.9
|
25.4
|
2542.3
|
33.8
|
3389.8
|
125 mm
|
5"
|
13.2
|
1324.2
|
26.4
|
2648.3
|
39.7
|
3972.4
|
52.9
|
5296.6
|
150 mm
|
6"
|
19.1
|
1906.8
|
38.1
|
3813.5
|
57.2
|
5720.3
|
76.2
|
7627.1
|
200 mm
|
8"
|
33.9
|
3389.8
|
67.7
|
6779.6
|
101.6
|
10169.4
|
135.5
|
13559.3
|
250 mm
|
10"
|
53
|
5296.6
|
105.9
|
10593.2
|
158.8
|
15889.8
|
211.8
|
21186.4
|
300 mm
|
12"
|
76.3
|
7627.1
|
152.5
|
15254.2
|
228.8
|
22881.3
|
305
|
30508.4
|
Model Number
Model
|
Basic Model
|
TGF450-
|
C
|
2
|
T
|
1
|
1
|
C
|
B
|
C
|
8
|
1
|
|
Process Connection
|
Flanged in-line
|
F
|
|
|
|
|
|
|
|
|
|
|
Insertion (NPT)
|
C
|
|
|
|
|
|
|
|
|
|
|
Insertion (NPT)
with anti-ejection design)
|
D
|
|
|
|
|
|
|
|
|
|
|
Inertion
(with flange)
|
G
|
|
|
|
|
|
|
|
|
|
|
Probe Length
|
290mm
(DN25~DN150)
|
1
|
|
|
|
|
|
|
|
|
|
440mm
(DN25~DN500)
|
2
|
|
|
|
|
|
|
|
|
|
Other
|
Q
|
|
|
|
|
|
|
|
|
|
Transmitte
|
Integral
|
T
|
|
|
|
|
|
|
|
|
Remote
|
R
|
|
|
|
|
|
|
|
|
Material
|
OCr18Ni9(304)
|
1
|
|
|
|
|
|
|
|
316
|
2
|
|
|
|
|
|
|
|
Other
|
Q
|
|
|
|
|
|
|
|
Pressure Rating
|
1.6 Mpa
|
1
|
|
|
|
|
|
|
2.5 Mpa
|
2
|
|
|
|
|
|
|
4 Mpa
|
3
|
|
|
|
|
|
|
6.3 Mpa
|
4
|
|
|
|
|
|
|
Flange Standard
|
For Chemical industry
|
A
|
|
|
|
|
|
GB China
|
B
|
|
|
|
|
|
ANSI
|
C
|
|
|
|
|
|
Other
|
Q
|
|
|
|
|
|
Max Temper
-ature
|
Standard (T≤150℃)
|
N
|
|
|
|
|
Other
|
Q
|
|
|
|
|
Enclosure
|
Comate blue enclosure
|
C
|
|
|
|
Transmitte
|
pulse/frequency + 4~20mA@HART
|
7
|
|
|
pulse/frequency + 4~20mA + RS485
|
8
|
|
|
Power supply
|
13.5~42VDC
|
1
|
|
85~265VAC 50/60Hz
|
2
|
|
Pipe size
|
please use 3 digit pipe size, such as DN50=050, DN300=300
|
XXX
|
Remark:
|
1. Ball valve, Hop-tap insertion tool and hot-tap hole opener are as accessoires,
please remark if you need any of them
|
2. Please indicate flow rate along with the model number selected
|
3. If you have any requirement that can not be fulfilled in this document,
please check with us to see the availability
|
4. The model selected in 1st line is the standard configuration with no accessories
|
|