Catalog | Video |
Execution standard: GB/T 7551-2008 Certificate (eqv OIML R60) Combined error: 0.027% Sealed to IEC 529: Protection grade: IP67 or IP68. Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water. |
|
Dimensions
(In mm. 1mm = 0.03937 inches)
Circuit Diagram:
Electrical Termination
4 Core cable standard lengths:1m
Diameter:Φ5
Connection: Refer to the following drawing:
Item Parameter |
C3 |
Unit |
Rated load (Emax): |
1,2,3,5,10 |
t |
Maximal numbers of load cell verification |
2000 |
d |
Minimum load cell verification intervals Intervals ( Vmin): |
0.02 |
% of rated load |
Rated output (Cn): |
2.0±0.1% |
mV/V |
Combined error: |
0.027 |
±% of rated output |
Temperature effect on sensitivity(Tkc): |
0.0024 |
±% of rated output/℃ |
Temperature effect on zero balance(Tk0): |
0.002 |
±% of rated output/℃ |
Zero balance: |
1.0 |
±% of rated output |
Input resistance(Rlc): |
775±5 |
Ω(Ohms) |
Output resistance(Ro): |
702±2 |
Ω(Ohms) |
Insulation resistance: |
≥5000 |
MΩ (Mega-Ohms) |
Safe overload: |
150 |
% of rated capability |
Ultimate overload: |
300 |
% of rated capability |
Operating temperature range: |
-20~+70/-20~+160 |
℃/ °F |
Recommend excitation: |
8~15 |
V( DC or AC) |
Maximum excitation: |
24 |
V( DC or AC) |
Material of elastomer: |
Alloy steel / Stainless steel |
|
Protection class: |
IP67/IP68 |
Hotline.
Ms. Vân Anh - 0904883101