Catalog | Video |
Execution standard: GB/T 7551-2008 Certificate (eqv OIML R60) Combined error : 0.027% Sealed to IEC 529: Protection grade: IP67 or IP68. Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water. |
|
Dimensions : (In mm. 1mm = 0.03937 inches)
CAP./SIZE |
A |
B |
C |
D |
E |
F |
H |
K |
L |
20~50 klbs |
190.5 |
114.3 |
57.1 |
31.8 |
12.7 |
19.1 |
63.5 |
60.3 |
3/8-24 |
100klbs |
231.8 |
152.4 |
79.4 |
44.5 |
15.9 |
27.0 |
64.3 |
101.6 |
1/2-20 |
200klbs |
295.3 |
203.2 |
114.3 |
63.5 |
15.9 |
27.0 |
89.7 |
139.7 |
5/8-18 |
300klbs |
355.8 |
252 |
127 |
76.2 |
19.1 |
33.3 |
109.5 |
139.7 |
3/4-16 |
Circuit Diagram:
Electrical Termination
4 Core cable standard lengths:
<=50klbs: 3.0 m, >=100klbs: 10m.
Diameter:Φ6
Connection:
Refer to the following drawing:
Notice:Do not change the length of cable, or lese, it will effect the sensitivity of load cell.
Specification
Item Parameter |
C3 |
Unit |
Rated load (Emax): |
20,30,50,100,200,300 |
klbs |
Maximal numbers of load cell verification |
3000 |
d |
Minimum load cell verification intervals Intervals ( Vmin): |
0.01 |
% of rated load |
Rated output (Cn): |
2.0±0.1% |
mV/V |
Combined error: |
0.015 |
-% of rated output |
Temperature effect on sensitivity(Tkc): |
0.0012 |
=% of rated output/ |
Temperature effect on zero balance(Tk0): |
0.0008 |
-% of rated output |
Zero balance: |
1.0 |
-% of rated output |
Input resistance(Rlc): |
775±5 |
Ω(Ohms) |
Output resistance(Ro): |
702±2 |
Ω(Ohms) |
Insulation resistance: |
≥5000 |
MΩ (Mega-Ohms) |
Safe overload: |
150 |
% of rated capability |
Ultimate overload: |
300 |
% of rated capability |
Operating temperature range: |
-20~+70/-20~+160 |
℃/ °F |
Recommend excitation: |
8~15 |
V( DC or AC) |
Maximum excitation: |
24 |
V( DC or AC) |
Material of elastomer: |
Alloy steel / Stainless steel |
|
Protection class: |
IP67/IP68 |
Hotline.
Ms. Vân Anh - 0904883101